Continuous decontamination of metal-polluted mine water using engineered hybrid adsorbent

Show simple item record

dc.contributor.author Muliwa, A. M.
dc.contributor.author Onyango, M.S.
dc.contributor.author Maity, A.
dc.contributor.author Ochieng, A.
dc.date.accessioned 2025-01-17T12:24:07Z
dc.date.available 2025-01-17T12:24:07Z
dc.date.issued 2025-01-17
dc.identifier.citation MuliwaAM2018 en_US
dc.identifier.uri http://localhost/xmlui/handle/123456789/6595
dc.description Proceedings of the Sustainable Research and Innovation Conference, JKUAT Main Campus, Kenya 2 - 4 May, 2018 en_US
dc.description.abstract Mining industries contribute enormously to water pollution through discharge of effluents contaminated with metals. Metals-polluted water is a threat to aquatic and human lives as well as the general ecosystem. Numerous conventional treatment methods are available for the removal of metals from mine water, but majority of them are costly, inefficient for trace metal concentration, and generate voluminous secondary sludge. Therefore, there is need for alternative low-cost novel technologies capable of reducing metal concentration in water to acceptable levels. Adsorption technology is increasingly receiving preference because it is simple in design, requires low initial cost, easy to operate, can remove contaminants in trace levels and the possibility to develop and employ wide variety of adsorbents. This study, therefore, explored the removal of manganese [Mn (II)] from aqueous solution using a bentonite/metal oxide hybrid (B/MeOx/H) hydrogels adsorbent packed in a fixed-bed reactor. The adsorption performance was examined by breakthrough behaviors under various experimental conditions such as bed height and influent flow rate. It was found that increase in bed height resulted to increase in both breakthrough and saturation times, while it was opposite with influent flow rate. The breakthrough curves were characterized by slightly flatter breakthrough curves for large bed depth and low flow rate. The overall adsorption performance of the fixed-bed column highly depended on the operating parameters. The experimental breakthrough data was sufficiently described by Yoon-Nelson model. Bed depth service time (BDST) predicted well the breakthrough times for different flow rates. The findings demonstrate that B/MeOx/H hydrogel adsorbent could effectively polish mine water laded with trace concentration of Mn (II). Keywords—Adsorption, Breakthrough, Hybrid, Mine water en_US
dc.description.sponsorship AM. Muliwa MS. Onyango A. Maity A. Ochieng en_US
dc.language.iso en en_US
dc.publisher JKUAT-COETEC en_US
dc.subject Adsorption en_US
dc.subject Breakthrough en_US
dc.subject Hybrid en_US
dc.subject Mine water en_US
dc.title Continuous decontamination of metal-polluted mine water using engineered hybrid adsorbent en_US
dc.type Article en_US